IFB AC Error Code List | Repair Skills
IFB air conditioners are reliable appliances, but encountering error codes is not uncommon. This guide will walk you through the troubleshooting steps for some common IFB AC error codes, ensuring you can address issues promptly and effectively.
FAILURE TYPE | ERROR CODE | RECOVERY |
IDU PCB communication failure | EO - CI | Auto |
ODU PCB communication failure | EO - CO | Auto |
Indoor room temperature sensor failure ( IRT ) | E1 | Auto |
Indoor coil temperature sensor failure ( IPT ) | E2 | Auto |
Outdoor coil temperature sensor failure ( OPT ) | E3 | Auto |
AC Cooling system abnormal | E4 | Power ON / OFF |
IDU PG fan motor / DC fan motor works abnormal / failure | E6 | Power ON / OFF |
Outdoor ambient temperature sensor failure | E7 | Auto |
ODU discharge temperature sensor failure | E8 | Auto |
IPM / Compressor driving control abnormal | E9 | Power ON / OFF |
ODU DC fan motor failure | EF | Power ON / OFF |
Abnormal Input voltage variation at time of compressor ON | EU | Power ON / OFF |
ODU inrush current bypass relay failure | FO | Power ON / OFF |
Compressor Rotor block | F1 | Power ON / OFF |
Vac abnormal ( Vac > 325 or Vac < 125 for 5 min | F4 | Power ON / OFF |
PFC protection | F5 | Auto |
a. Compressor Lack of phase b . Flux out of range | F6 | Power ON / OFF |
IPM module temperature protection | F7 | Auto |
IFB AC Protection Error Code
PROTECTION TYPE | PROTECTION CODE |
IPM module protection | PO |
Over and under voltage protection | P1 |
Over current protection | P2 |
ODU discharge over temperature protection | P4 |
IDU coil low temperature protection | P5 |
ODU coil over temperature protection in cool mode | P6 |
ODU ambient over & under temperature protection | P8 |
Compressor driving protection ( Load abnormal ) | P9 |
IDU PCB Communication Failure (EO - CI)
Error Code: EO - CI
Recovery: Automatic
Solution:
- Communication Analysis: Conduct a thorough analysis of IDU PCB communication.
- Obstruction Check: Examine for any physical obstructions affecting communication.
- Diagnostic Tools: Utilize diagnostic tools to pinpoint communication issues.
- Manual Reference: Refer to the technical manual for further diagnosis and resolution.
ODU PCB Communication Failure (EO - CO)
Error Code: EO - CO
Recovery: Automatic
Solution:
- Communication Protocol: Review ODU PCB communication protocol.
- Signal Testing: Conduct signal testing to identify communication irregularities.
- Technical Documentation: Consult technical documentation for precise communication troubleshooting steps.
- Advanced Tools: Use advanced diagnostic tools to assess communication health.
Indoor Room Temperature Sensor Failure (IRT)
Error Code: E1
Recovery: Automatic
Solution:
- Wait for Recovery: In most cases, the system will automatically recover.
- Ensure Proper Airflow: Check and ensure there's proper airflow around the indoor unit.
- Check for Blockages: Inspect for any blockages affecting the temperature sensor.
Indoor Coil Temperature Sensor Failure (IPT)
Error Code: E2
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to recover automatically.
- Ensure Airflow: Confirm there are no obstructions around the indoor coil.
- Check Sensor: Inspect the temperature sensor for any issues.
Outdoor Coil Temperature Sensor Failure (OPT)
Error Code: E3
Recovery: Automatic
Solution:
- Automatic Recovery: Wait for the system to recover on its own.
- Check for Obstructions: Examine the outdoor unit for any obstacles.
AC Cooling System Abnormal (E4)
Error Code: E4
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Check for Refrigerant Issues: Inspect the refrigerant levels and address any abnormalities.
IDU PG Fan Motor / DC Fan Motor Works Abnormal (E6)
Error Code: E6
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait briefly, and then turn it back on.
- Fan Motor Inspection: Inspect the indoor fan motor and DC fan motor for any abnormalities.
Outdoor Ambient Temperature Sensor Failure (E7)
Error Code: E7
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to recover automatically.
- Obstacle Check: Ensure there are no obstacles affecting the ambient temperature sensor.
ODU Discharge Temperature Sensor Failure (E8)
Error Code: E8
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the AC to recover on its own.
- Check for Blockages: Inspect for any blockages around the outdoor unit.
IPM / Compressor Driving Control Abnormal (E9)
Error Code: E9
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Check Electrical Connections: Inspect electrical connections for any loose or damaged components.
- Professional Assistance: If the problem persists, consult with a professional HVAC technician for advanced diagnostics.
ODU DC Fan Motor Failure (EF)
Error Code: EF
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Fan Motor Inspection: Inspect the ODU DC fan motor for failures or abnormalities.
- Advanced Troubleshooting: Use advanced troubleshooting techniques for a detailed analysis.
Abnormal Input Voltage Variation at Time of Compressor ON (EU)
Error Code: EU
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Voltage Analysis: Analyze input voltage variations during compressor ON cycles.
- Technical Assessment: Perform a technical assessment of voltage fluctuations.
ODU Inrush Current Bypass Relay Failure (FO)
Error Code: FO
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Relay Inspection: Inspect the inrush current bypass relay for failures.
- Advanced Troubleshooting: Use advanced troubleshooting techniques for relay analysis.
- Technical Consultation: Consult with technical experts for precise guidance.
Compressor Rotor Block (F1)
Error Code: F1
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Rotor Block Analysis: Analyze the compressor rotor for blockages.
- Technical Inspection: Inspect the compressor rotor for abnormalities.
- Technical Support: If issues persist, seek support from technical experts.
Vac Abnormal (Vac {'>'} 325 or Vac {'<'} 125 for 5 min) (F4)
Error Code: F4
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Voltage Check: Confirm that the voltage is within the acceptable range.
PFC Protection (F5)
Error Code: F5
Recovery: Automatic
Solution:
- Wait for Automatic Recovery: Allow the AC to recover automatically.
- Check Power Supply: Ensure stable power supply to the AC unit.
- Professional Assistance: If the error persists, consult with a service technician for advanced diagnostics.
Compressor Lack of Phase / Flux Out of Range (F6)
Error Code: F6
Recovery: Power ON / OFF
Solution:
- Power Cycle: Turn off the AC, wait for a few minutes, and then power it back on.
- Check Electrical Phases: Verify the electrical phases for the compressor.
IPM Module Temperature Protection (F7)
Error Code: F7
Recovery: Automatic
Solution:
- Wait for Automatic Recovery: Allow the AC to recover automatically.
- Temperature Check: Ensure the ambient temperature around the IPM module is within the specified range.
IPM Module Protection (PO)
Error Code: PO
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the AC to recover automatically.
- Module Inspection: Conduct a detailed inspection of the IPM module for visible damage or anomalies.
- Advanced Analysis: Use specialized diagnostic tools for in-depth analysis of the module's performance.
- Technical Assistance: Collaborate with technical experts for precise guidance in resolving the issue.
Over and Under Voltage Protection (P1)
Error Code: P1
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to stabilize and recover automatically.
- Voltage Check: Utilize specialized equipment to confirm that the power supply voltage is within the acceptable range.
- Power Supply Inspection: Conduct a comprehensive inspection of the power supply to ensure stability.
- Advanced Troubleshooting: Employ advanced troubleshooting techniques for a detailed analysis of voltage variations.
Over Current Protection (P2)
Error Code: P2
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to recover on its own.
- Current Analysis: Utilize specialized tools to check for any abnormal current flow within the system.
- Professional Assistance: Collaborate with fellow technicians or specialists for advanced diagnostics.
- Documentation Reference: Refer to technical documentation for precise steps in resolving overcurrent issues.
ODU Discharge Over Temperature Protection (P4)
Error Code: P4
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the AC to cool down and recover automatically.
- Temperature Analysis: Utilize temperature sensors and gauges to check for abnormal heat in the outdoor unit.
- Airflow Inspection: Ensure proper airflow around the outdoor unit for efficient cooling.
- Collaboration with Experts: Seek collaboration with experts for a detailed analysis of temperature-related issues.
IDU Coil Low Temperature Protection (P5)
Error Code: P5
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to warm up and recover automatically.
- Temperature Check: Use specialized tools to ensure the ambient temperature is within the operating range.
- Collaboration with Colleagues: Collaborate with fellow technicians for insights into resolving low-temperature protection issues.
- Professional Assistance: Consult with senior technicians or specialists for guidance in complex scenarios.
ODU Coil Over Temperature Protection in Cool Mode (P6)
Error Code: P6
Recovery: Automatic
Solution:
- Automatic Recovery: Wait for the AC to cool down and recover automatically.
- Cooling Mode Verification: Confirm that the AC is operating in the correct cooling mode using diagnostic tools.
- Collaboration with Experts: Seek collaboration with HVAC specialists for a detailed analysis of cooling-related issues.
- Advanced Troubleshooting: Employ advanced troubleshooting techniques for in-depth resolution.
ODU Ambient Over & Under Temperature Protection (P8)
Error Code: P8
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to stabilize and recover automatically.
- Temperature Check: Use specialized tools to ensure the outdoor ambient temperature is within the specified range.
- Collaboration with Technicians: Collaborate with fellow technicians for insights into resolving ambient temperature protection issues.
- Documentation Reference: Refer to technical documentation for precise steps in addressing ambient temperature variations.
Compressor Driving Protection (Load Abnormal) (P9)
Error Code: P9
Recovery: Automatic
Solution:
- Automatic Recovery: Allow the system to recover automatically.
- Load Analysis: Utilize specialized tools to check for abnormal loads on the compressor.
- Collaboration with Colleagues
- Collaboration with Colleagues: Work collaboratively with fellow technicians for insights into resolving load-related issues.
- Advanced Troubleshooting: Employ advanced troubleshooting techniques and tools for an in-depth analysis of compressor load abnormalities.
- Documentation Reference: Refer to technical documentation for precise steps in addressing load-related protection