Lg inverter split air conditioner error code

 Lg inverter split air conditioner error code

By Amar Jeet Kumawat 

Error CodeDescription
21DC Peak (IPM) Fault – Compressor DC voltage is too high
22CT2 (Max  CT) – Alternating current input too high
23DC Link Low Voltage
25AC Low/High Voltage
26DC Comp Position Error (not providing rotation – locking)
27PSC Fault – Current to inverter compressor between AC and DC converter is too high
28Inverter Compressor DC voltage is too high
29Comp Phase Over-current – Inverter compressor amperage is too high
31Current-to-current transformer (CT) thermistor is too low
32Inverter Compressor Discharge pipe overheat
34High-pressure sensor high
35Low-pressure sensor low
36/38Refrigerant Leak detection
37Exceed the compression ration limit                                                                             
40CT sensor error – Thermistor is disconnected or shorted out
41Discharge Pipe sensor error – INV is disconnected or shorted out
42Low-Pressure sensor error
43High-Pressure sensor error
44Outdoor air sensor error – Disconnected or shorted out
45Condenser middle pipe sensor error – Disconnected or shorted out
46Suction pipe sensor error – Disconnected or shorted out
48Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out
51Excess capacity – Mismatch between IDU and ODU
53Communication error – between the IDU and ODU
60Outdoor unit printed circuit board (PCB) EEPROM checksum error
61Condenser coil temperature is too high
62Heat sink sensor temperature – high
63Condenser coil pipe thermistor temperature is low
65Heat sink thermistor has disconnected or shorted out
67BLDC motor fan lock
72Detect 4-way valve transfer failure
93Communication error

Other LG AC Error Codes:

Error CodePossible CauseSolution
Code appears in the display. F1,F2 or F3Air conditioner is in FAN mode and the number shown is the set fan speed.This is normal. The air conditioner is working properly.
FLThe water collection tank is full.Empty the water collection tank.
CH01Short or open circuit in the indoor air thermistor.Unplug the air conditioner and contact your authorized LG service center.