Lg inverter split air conditioner error code
Lg inverter split air conditioner error code
By Amar Jeet Kumawat
| Error Code | Description |
| 21 | DC Peak (IPM) Fault – Compressor DC voltage is too high |
| 22 | CT2 (Max CT) – Alternating current input too high |
| 23 | DC Link Low Voltage |
| 25 | AC Low/High Voltage |
| 26 | DC Comp Position Error (not providing rotation – locking) |
| 27 | PSC Fault – Current to inverter compressor between AC and DC converter is too high |
| 28 | Inverter Compressor DC voltage is too high |
| 29 | Comp Phase Over-current – Inverter compressor amperage is too high |
| 31 | Current-to-current transformer (CT) thermistor is too low |
| 32 | Inverter Compressor Discharge pipe overheat |
| 34 | High-pressure sensor high |
| 35 | Low-pressure sensor low |
| 36/38 | Refrigerant Leak detection |
| 37 | Exceed the compression ration limit |
| 40 | CT sensor error – Thermistor is disconnected or shorted out |
| 41 | Discharge Pipe sensor error – INV is disconnected or shorted out |
| 42 | Low-Pressure sensor error |
| 43 | High-Pressure sensor error |
| 44 | Outdoor air sensor error – Disconnected or shorted out |
| 45 | Condenser middle pipe sensor error – Disconnected or shorted out |
| 46 | Suction pipe sensor error – Disconnected or shorted out |
| 48 | Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out |
| 51 | Excess capacity – Mismatch between IDU and ODU |
| 53 | Communication error – between the IDU and ODU |
| 60 | Outdoor unit printed circuit board (PCB) EEPROM checksum error |
| 61 | Condenser coil temperature is too high |
| 62 | Heat sink sensor temperature – high |
| 63 | Condenser coil pipe thermistor temperature is low |
| 65 | Heat sink thermistor has disconnected or shorted out |
| 67 | BLDC motor fan lock |
| 72 | Detect 4-way valve transfer failure |
| 93 | Communication error |
Other LG AC Error Codes:
| Error Code | Possible Cause | Solution |
|---|---|---|
| Code appears in the display. F1,F2 or F3 | Air conditioner is in FAN mode and the number shown is the set fan speed. | This is normal. The air conditioner is working properly. |
| FL | The water collection tank is full. | Empty the water collection tank. |
| CH01 | Short or open circuit in the indoor air thermistor. | Unplug the air conditioner and contact your authorized LG service center. |